| 83 | WellinTech KingView Client Detection | Nessus Network Monitor | SCADA | | | info |
| 8371 | IEC 60870-5-104 Client Detection (SCADA) | Nessus Network Monitor | SCADA | 2014/9/24 | 2015/6/1 | info |
| 86 | Synchrophaser (IEEE C37.118) Server Detection via TCP | Nessus Network Monitor | SCADA | | | info |
| 8610 | Schneider Electric SCADA Expert ClearSCADA 2005 / 2007 / 2009 < 2009 R2.4 / 2010 < 2010 R1.1 Remote Authentication Bypass | Nessus Network Monitor | SCADA | 2015/7/17 | 2019/3/6 | medium |
| 89 | DNP3/TCP Protocol Detection | Nessus Network Monitor | SCADA | | | info |
| 9051 | General Electric's MDS PulseNET Version Detection | Nessus Network Monitor | SCADA | 2016/1/15 | 2017/1/31 | info |
| 94 | IEC 60870-5-104 Server Detection | Nessus Network Monitor | SCADA | | | info |
| 9560 | Navis WebAccess Web Application Detection (SCADA) | Nessus Network Monitor | SCADA | 2016/9/12 | 2016/9/12 | info |
| 9951 | Advantech WebAccess < 6.0-2008.06.06 Remote Authentication Bypass | Nessus Network Monitor | SCADA | 2017/2/14 | 2019/3/6 | medium |
| 6445 | Schneider Electric ClearSCADA 2010 R2 < 2013 R2 Remote DoS | Nessus Network Monitor | SCADA | 2014/4/25 | 2019/3/6 | low |
| 6697 | Ecava IntegraXor < 4.0.4283 ActiveX Remote Buffer Overflow | Nessus Network Monitor | SCADA | 2013/2/19 | 2019/3/6 | high |
| 7142 | Progea Movicon < 11.2 Build 1086 Multiple Vulnerabilities | Nessus Network Monitor | SCADA | 2014/9/10 | 2018/8/16 | critical |
| 720003 | Siemens WinCC and SIMATIC HMI Panels Default Password | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | high |
| 720006 | Siemens WinCC and SIMATIC HMI Panels < 11.0.2.1 Header Injection | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | medium |
| 720010 | Siemens WinCC and SIMATIC HMI Panels < 11.0.2.1 Buffer Overflow | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | high |
| 720016 | Siemens Scalance S Security Module Firewall < 2.3.0.3 Buffer Overflow | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | medium |
| 720017 | Siemens SCALANCE X Industrial Ethernet Switch Multiple Versions Buffer Overflow | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | high |
| 720024 | Emerson DeltaV Multiple Devices Multiple Versions Denial of Service | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | medium |
| 720027 | Rockwell Automation/Allen-Bradley Ethernet/IP Products Improper Access Control | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | high |
| 720029 | Rockwell Automation/Allen-Bradley Ethernet/IP Products Information Exposure | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | medium |
| 720032 | Schneider Electric Quantum and Premium PLC CSRF | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | medium |
| 720035 | Schneider Electric Trio J-Series License Free Ethernet Radio 3.6.0 <= 3.6.3 Hardcoded Encryption Key | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | critical |
| 720037 | Siemens SCALANCE X200 IRT Switches < 5.1.0 HTTP Command Execution | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | high |
| 720048 | Siemens SIMATIC S7-1200 2.x < 4.x XSS | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | medium |
| 720054 | Schneider Electric ETG3000 FactoryCast HMI Gateway < 1.60 IR 04 Unauthenticated Access | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | high |
| 720056 | Omron Multiple Products Reversible Password Storage | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | low |
| 720067 | Siemens SIMATIC S7-1200 CPU < 4.1.3 CSRF | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | high |
| 720074 | Honeywell Midas Gas Detectors Path Cleartext Transmission | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | critical |
| 720081 | Schneider Electric PowerLogic PM8ECC < 2.651 XSS | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | medium |
| 720089 | Mitsubishi MELSEC-Q Ethernet Interface Modules Denial of Service | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | high |
| 720093 | Siemens Desigo PX Web Modules Insufficient Entropy | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | high |
| 720095 | Rockwell Automation/Allen-Bradley Multiple Devices Cleartext Transmission | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | high |
| 720097 | Emerson DeltaV Wireless I/O Cards (WIOC) 13.3 Authentication Bypass | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | medium |
| 720105 | Siemens SICAM RTUs SM-2556 COM Modules Authentication Bypass | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | medium |
| 720106 | Siemens SICAM RTUs SM-2556 COM Modules XSS | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | medium |
| 720112 | Schneider Electric Modicon M340 Controllers Denial of Service | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | high |
| 720117 | Schneider Electric Modicon Modbus Protocol Violation of Secure Design Principles | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | medium |
| 720122 | Siemens OZW Devices Authentication Bypass | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | high |
| 720128 | Rockwell Automation/Allen-Bradley PanelView Plus 6 HMIs Missing Authorization | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | high |
| 720129 | ABB VSN300 WiFi Logger Card Authentication Bypass | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | medium |
| 720147 | Emerson ControlWave Micro <= 05.78.00 Buffer Overflow | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | high |
| 720156 | Rockwell Automation 1756-EWEB <= 5.001 and 1768-EWEB <= 2.005 SNMP Denial of Service | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | high |
| 720160 | Schneider Electric OPC Factory Server (OFS) <= 3.5 Denial of Service | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | high |
| 720170 | Siemens SIMATIC S7-400 (all versions) and S7-410 < 8.2.1 Multiple Connections DOS | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | high |
| 720171 | Siemens SIMATIC S7-400 (all versions) and S7-410 < 8.2.1 Multiple Packets DOS | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | high |
| 720174 | Emerson Multiple RTUs Network Beacon Leak Metadata | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | critical |
| 720177 | Omron NS HMIs 1.1 and <= 1.3 Bypass Authentication | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | critical |
| 720178 | Rockwell Automation RSLinx Classic < 2.58 DOS | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | critical |
| 720194 | Siemens SIMATIC S7-1500 PLCs < 1.5 Random Number Generator Insufficient Entropy | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | high |
| 720197 | Siemens SIMATIC S7-1200 PLCs < 4.0 HTTP Packets DOS | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | high |