763029 | Beckhoff CP6603-0001-0020 Industrial Computer Detection | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | info |
763055 | Beckhoff CP6731-0002-0060 Industrial Computer Detection | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | info |
763068 | Beckhoff CP6742-0000-0060 Industrial Computer Detection | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | info |
763075 | Beckhoff CP6713-0001-0060 Industrial Computer Detection | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | info |
763079 | Beckhoff CP6733-0000-0060 Industrial Computer Detection | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | info |
763082 | Beckhoff CP6707-0000-0050 Industrial Computer Detection | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | info |
755624 | Omron NJ Series PLC Detection | Nessus Network Monitor | SCADA | | | info |
720143 | Siemens SCALANCE X Switches XSS | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | medium |
720314 | Siemens Industrial Real-Time (IRT) Devices Improper Input Validation (ICSA-19-283-01) | Nessus Network Monitor | SCADA | 2019/11/3 | 2019/11/3 | high |
720107 | Siemens SICAM RTUs SM-2556 COM Modules Code Injection | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | critical |
8397 | Ecava IntegraXor < 4.1.4369 Project Directory Information Disclosure | Nessus Network Monitor | SCADA | 2014/9/19 | 2019/3/6 | high |
153 | Siemens 44x-1 RNA CP Remote Administrative Action Execution | Nessus Network Monitor | SCADA | 2019/5/21 | 2019/9/30 | high |
720113 | Rockwell Automation ControlLogix 5580 and CompactLogix 5380 Resource Exhaustion (ICSA-17-094-05) | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | medium |
8609 | Trihedral VTScada 6.5 through 9.x <= 9.1.19, 10.x <= 10.2.21, and 11.x <= 11.1.08 Remote Denial of Service | Nessus Network Monitor | SCADA | 2014/12/18 | 2019/3/6 | high |
720095 | Rockwell Automation/Allen-Bradley Multiple Devices Cleartext Transmission | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | high |
720161 | Schneider Electric Modicon TM221CE16R 1.3.3.3 Information Disclosure | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | critical |
151 | Siemens S7-300 Packet Handling Remote DOS | Nessus Network Monitor | SCADA | 2019/5/21 | 2019/9/30 | high |
720089 | Mitsubishi MELSEC-Q Ethernet Interface Modules Denial of Service | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | high |
720092 | Siemens SIMATIC CP 1543-1 < 2.0.28 Denial of Service | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | medium |
64 | Rockwell Automation/Allen-Bradley MicroLogix 1400 Series A <= 7 and Series B <= 15.000 DNP3 Remote DoS | Nessus Network Monitor | SCADA | 2019/5/21 | 2019/9/30 | high |
720046 | Omron NS HMIs 8.1xx <= 8.68x CSRF | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | medium |
720193 | Siemens SIMATIC S7-1200 PLCs < 4.0 Random Number Generator Insufficient Entropy | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | high |
720195 | Siemens SIMATIC S7-1200 PLCs < 4.0 PROFINET Packets DOS | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | medium |
720198 | Siemens SIMATIC S7-1500 PLCs < 1.5 Improper Resource Release DOS | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | high |
720202 | Siemens SIMATIC S7-1500 PLCs < 1.5 HTTPS Packets DOS | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | high |
148 | Siemens SCALANCE X-300 Family Switches HTTP Request Handling Remote DOS | Nessus Network Monitor | SCADA | 2019/5/21 | 2019/9/30 | high |
7162 | Accuenergy Acuvim II AXM-NET 3.04 Multiple Vulnerabilities | Nessus Network Monitor | SCADA | 2014/12/10 | 2018/8/16 | high |
720194 | Siemens SIMATIC S7-1500 PLCs < 1.5 Random Number Generator Insufficient Entropy | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | high |
720199 | Siemens SIMATIC S7-1200 PLCs < 4.0 ISO-TSAP Packets DOS | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | high |
152 | Siemens S7-300 Protection-level 2 Configuration Unspecified Remote Credential Disclosure | Nessus Network Monitor | SCADA | 2019/5/21 | 2019/9/30 | medium |
720276 | Siemens SIMATIC HMI Panels and TIA Portal <= v15.1 Update 1 XSS (ICSA-19-134-09) | Nessus Network Monitor | SCADA | 2019/7/31 | 2019/9/30 | medium |
720298 | Schneider Electric Modicon Controllers Denial of Service (ICSA-19-183-01) | Nessus Network Monitor | SCADA | 2019/9/17 | 2019/9/30 | high |
720309 | Siemens SIMATIC PCS7 < V9.1 and TIA Portal < 15.2 Unrestricted Upload of File with Dangerous Type (ICSA-19-192-02) | Nessus Network Monitor | SCADA | 2019/10/28 | 2019/10/28 | high |
720023 | Rockwell Automation Allen-Bradley Multiple Controllers Multiple Versions Denial of Service | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | high |
720305 | Siemens Sinamics Perfect Harmony GH180 Drives Uncontrolled Resource Consumption DoS (ICSA-19-134-05) | Nessus Network Monitor | SCADA | 2019/10/15 | 2019/10/15 | high |
720024 | Emerson DeltaV Multiple Devices Multiple Versions Denial of Service | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | medium |
720285 | Yokogawa License Manager Service Input Validation Error (ICSA-19-029-01) | Nessus Network Monitor | SCADA | 2019/8/28 | 2019/9/30 | critical |
720311 | Siemens CP, SIMATIC, SIMOCODE, SINAMICS, SITOP, and TIM Out-of-bounds Read (ICSA-19-099-06) | Nessus Network Monitor | SCADA | 2019/10/28 | 2019/10/28 | high |
720164 | Siemens SIMATIC ET 200SP 2.0 < 2.1.6 and SIMATIC S7-1500 2.0 < 2.5 DOS | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | high |
720257 | Siemens CP 1604 and 1616 <= v2.8 Cleartext Transmission of Sensitive Information | Nessus Network Monitor | SCADA | 2019/6/5 | 2019/9/30 | critical |
720228 | Rockwell Automation Stratix Ethernet Switches < 15.3 IOS DHCP Reload | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | high |
720038 | Siemens SCALANCE X200 IRT Switches < 5.1.0 SNMP Command Execution | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | high |
7225 | Siemens S7-300 Series PLC CPU Firmware <= 3.2.11 DoS | Nessus Network Monitor | SCADA | 2016/9/9 | 2018/8/16 | high |
720240 | Schneider Electric Modicon Multiple Controllers Buffer Overflow | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | high |
720082 | Yokogawa STARDOM FCN/FCJ Controllers R1.01 <= R4.01 Authentication Bypass | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | high |
720060 | Siemens RUGGEDCOM WIN Multiple Devices Authentication Bypass | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | critical |
720244 | Schneider Electric Modicon Multiple Controllers Unauthorized Password Delete | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | critical |
720269 | Siemens SIMATIC S7-1500 PLCs < v2.5 Multiple DoS (ICSA-19-036-04) | Nessus Network Monitor | SCADA | 2019/7/23 | 2019/9/30 | high |
141 | Siemens SIMATIC S7-1200 Series 2.x PLC Private Key Exposure | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | medium |
720068 | Rockwell Automation/Allen-Bradley MicroLogix Multiple Devices SQL Injection | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | medium |