701084 | VxWorks 6.x < 6.9.4 Multiple Vulnerabilities (URGENT/11) | Nessus Network Monitor | IoT | 2019/7/29 | 2019/7/29 | critical |
7279 | Axis Camera Multiple Products RCE (Devil's Ivy) | Nessus Network Monitor | IoT | 2017/7/19 | 2018/8/16 | high |
235 | Siemens CP 343-1 Lean Detection | Nessus Network Monitor | SCADA | | | info |
245 | Siemens S7 PLC communicating with an Application Server | Nessus Network Monitor | SCADA | | | info |
251 | Schneider Electric Modicon M221 PLC Detection | Nessus Network Monitor | SCADA | 2019/5/13 | 2019/9/30 | info |
261 | Schneider Electric Powerlink G3 3000 Controller Detection | Nessus Network Monitor | SCADA | 2019/5/21 | 2019/9/30 | info |
266 | Schneider Electric Modicon X80 Peripheral Remote IO Adaptor PRA0100 Detection | Nessus Network Monitor | SCADA | 2019/5/21 | 2019/9/30 | info |
269 | Schneider Electric PowerLogic PM3000 Power Meter Detection | Nessus Network Monitor | SCADA | 2019/5/21 | 2019/9/30 | info |
271 | Schneider Electric PowerLogic PM210 Power Meter Detection | Nessus Network Monitor | SCADA | 2019/5/21 | 2019/9/30 | info |
3555 | TPKT Server Detection | Nessus Network Monitor | SCADA | 2014/11/24 | 2017/3/7 | info |
3853 | Modicon PLC HTTP Server Default Username/Password (SCADA) | Nessus Network Monitor | SCADA | 2006/12/11 | 2016/9/30 | high |
39 | MODBUS/TCP 'Return Query Data' Function Code Detection (SCADA) | Nessus Network Monitor | SCADA | | | info |
155 | Siemens S7 Read SZL Request | Nessus Network Monitor | SCADA | | | info |
158 | Siemens S7 Read Variable Response | Nessus Network Monitor | SCADA | | | info |
179 | Siemens TIA Portal Detected | Nessus Network Monitor | SCADA | | | info |
181 | Siemens S7-1200 Device State Change Request Detected | Nessus Network Monitor | SCADA | | | info |
185 | OPC UA Client Detection via HTTPS | Nessus Network Monitor | SCADA | | | info |
187 | OPC UA Client Error Detection | Nessus Network Monitor | SCADA | | | info |
189 | OPC UA Client Message Type Detection | Nessus Network Monitor | SCADA | | | info |
197 | Rockwell Automation/Allen-Bradley SoftLogix 5800 Controller | Nessus Network Monitor | SCADA | | | info |
201 | Emerson Micro Motion 5700 Coriolis Field Mount Transmitter | Nessus Network Monitor | SCADA | 2019/5/21 | 2019/9/30 | info |
216 | Siemens S7 Comm Plus Protocol Detection | Nessus Network Monitor | SCADA | | | info |
231 | Siemens SIMOCODEproV EIP | Nessus Network Monitor | SCADA | 2019/5/21 | 2019/9/30 | info |
46 | MODBUS/TCP Server Detection | Nessus Network Monitor | SCADA | | | info |
49 | DNP3/TCP 'Cold Restart' Function Code Detection (SCADA) | Nessus Network Monitor | SCADA | | | info |
28 | Siemens S7-1200 Series PLC Detection | Nessus Network Monitor | SCADA | | | info |
285 | OT Model Name Detection | Nessus Network Monitor | SCADA | | | info |
287 | Microsoft Windows Underlying OS Detection | Nessus Network Monitor | SCADA | | | info |
115 | MODBUS/TCP 'Illegal Data Address' Exception Code Detection (SCADA) | Nessus Network Monitor | SCADA | | | info |
121 | MODBUS/TCP 'Gateway Target Device Failed to Respond' Exception Code Detection (SCADA) | Nessus Network Monitor | SCADA | | | info |
124 | DNP3/TCP 'Write' Function Code Detection (SCADA) | Nessus Network Monitor | SCADA | | | info |
125 | DNP3/TCP 'Select' Function Code Detection (SCADA) | Nessus Network Monitor | SCADA | | | info |
128 | DNP3/TCP 'Direct Operate/No Response' Function Code Detection (SCADA) | Nessus Network Monitor | SCADA | | | info |
752197 | Mitsubishi FX3U-2HSY-ADP Position Controller Detection | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | info |
752200 | Mitsubishi LD75D4 Position Controller Detection | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | info |
752202 | Mitsubishi LD75P2 Position Controller Detection | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | info |
752204 | Mitsubishi QD70D4 Position Controller Detection | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | info |
752208 | Mitsubishi QD72P3C3 Position Controller Detection | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | info |
752213 | Rockwell Automation/Allen-Bradley SLC 500 5/04 PLC Detection | Nessus Network Monitor | SCADA | | | info |
752216 | Rockwell Automation RSLogix 5000 Application Detection | Nessus Network Monitor | SCADA | 2019/5/13 | 2019/9/30 | info |
752219 | Rockwell Automation DTAM Plus - Operator Interface Module 2707-xxxPxxD Generic | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | info |
752226 | Rockwell Automation Bulletin 160 Analog 0.37kW 230v AC Drive | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | info |
752248 | Rockwell Automation Bulletin 160 Preset 2.2 kW 460v AC Drive | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | info |
752252 | Rockwell Automation 160-Signal Follower v4.xx DN1 v2.0 Standard 160-SF1 AC Drive | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | info |
752260 | Rockwell Automation Bul 1329I 1HP 230V 1PH 56FR Std AC Drive | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | info |
752266 | Rockwell Automation Bul 1329I 1HP 230V 3PH 56FR Std AC Drive | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | info |
752268 | Rockwell Automation Bul 1329I 1HP 230V 3PH 140FR Std AC Drive | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | info |
752270 | Rockwell Automation Bul 1329I 2HP 230V 3PH 140FR Std AC Drive | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | info |
752279 | Rockwell Automation Bul 1329I 3HP 460V 3PH 180FR Loc AC Drive | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | info |
752285 | Rockwell Automation E3 Plus (1-5A) 193/592-EC2A Motor Overload | Nessus Network Monitor | SCADA | 2019/5/8 | 2019/9/30 | info |