90599 | Rockwell Automation MicroLogix 1400 PLC Default Credentials | Nessus | SCADA | 2016/4/20 | 2024/7/17 | critical |
91622 | Cogent DataHub < 6.4.3 OPC Client Reconnection Saturation Remote DoS | Nessus | SCADA | 2016/6/15 | 2024/5/20 | medium |
91624 | Cogent DataHub < 6.4.7 Incoming DDE Connection Handling Remote DoS | Nessus | SCADA | 2016/6/15 | 2024/5/20 | medium |
91625 | Panasonic Control FPWIN Pro Detection | Nessus | SCADA | 2016/6/15 | 2024/7/24 | info |
95714 | Siemens SINEMA Server < 13 SP2 Unquoted Service Path Local Privilege Escalation (SSA-701708) | Nessus | SCADA | 2016/12/12 | 2024/7/24 | medium |
62032 | Sielco Sistemi Winlog < 2.07.17 Multiple Vulnerabilities | Nessus | SCADA | 2012/9/10 | 2024/5/20 | high |
62965 | IOServer XML Server URI Directory Traversal Arbitrary File Access | Nessus | SCADA | 2012/11/19 | 2024/7/24 | medium |
63428 | Siemens Automation License Manager Multiple Vulnerabilities | Nessus | SCADA | 2013/1/9 | 2024/5/20 | high |
64296 | Schneider Electric Interactive Graphical SCADA System dc.exe Unspecified Buffer Overflow | Nessus | SCADA | 2013/1/30 | 2024/5/20 | critical |
65193 | CoDeSys Gateway Service Detection | Nessus | SCADA | 2013/3/11 | 2024/7/17 | info |
70415 | ProSoft RadioLinx ControlScape Install Detection | Nessus | SCADA | 2013/10/14 | 2024/7/24 | info |
70530 | Siemens SCALANCE X-200 Authentication Bypass | Nessus | SCADA | 2013/10/21 | 2024/5/20 | critical |
70558 | ClearSCADA Web Server Detection | Nessus | SCADA | 2013/10/23 | 2024/7/24 | info |
70592 | KEPServerEX < 5.12.140.0 Denial of Service | Nessus | SCADA | 2013/10/24 | 2024/5/20 | high |
99168 | Siemens S7 Protocol Support Detection | Nessus | SCADA | 2017/4/3 | 2024/7/17 | info |
77375 | Honeywell FALCON XL Web Controller Multiple Vulnerabilities | Nessus | SCADA | 2014/8/25 | 2024/5/20 | high |
77376 | CODESYS WAGO WebVisu Detection | Nessus | SCADA | 2014/8/25 | 2014/8/25 | info |
76573 | Triangle MicroWorks SCADA Data Gateway Detection (credentialed check) | Nessus | SCADA | 2014/7/17 | 2024/7/24 | info |
90001 | PACTware Detection | Nessus | SCADA | 2016/3/17 | 2024/7/24 | info |
88839 | Advantech WebAccess openWidget Script Path Traversal Remote File Disclosure | Nessus | SCADA | 2016/2/18 | 2024/7/24 | high |
88412 | iniNet SpiderControl SCADA Editor Detection | Nessus | SCADA | 2016/1/27 | 2024/7/24 | info |
52994 | Movicon TcpUploadServer Detection | Nessus | SCADA | 2011/3/25 | 2024/7/17 | info |
59376 | WellinTech KingView 6.53 < 2011-11-20 HistoryServer.exe nettransdll.dll Module Op-code 3 Packet Parsing Remote Overflow | Nessus | SCADA | 2012/6/5 | 2024/7/24 | critical |
58953 | Microsys PROMOTIC < 8.1.5 Multiple Vulnerabilities | Nessus | SCADA | 2012/5/1 | 2024/5/20 | high |
72556 | 3S CODESYS Development System V2 Installed (Windows) | Nessus | SCADA | 2014/2/18 | 2024/7/24 | info |
72557 | 3S CoDeSys Runtime Toolkit NULL Pointer Dereference (credentialed check) | Nessus | SCADA | 2014/2/18 | 2024/5/20 | medium |
72558 | 3S CoDeSys Runtime Toolkit NULL Pointer Dereference (uncredentialed check) | Nessus | SCADA | 2014/2/18 | 2024/5/20 | medium |
73516 | RuggedCom RuggedOS SNMP Protocol Unspecified DoS | Nessus | SCADA | 2014/4/15 | 2024/5/20 | high |
73642 | Advantech WebAccess Stored Cross-Site Scripting | Nessus | SCADA | 2014/4/14 | 2024/7/24 | low |
57600 | Modicon Quantum TFTP Arbitrary File Upload | Nessus | SCADA | 2012/1/19 | 2024/7/17 | high |
66761 | Mitsubishi MX Component ActiveX Remote Code Execution | Nessus | SCADA | 2013/6/3 | 2024/7/24 | critical |
64487 | RuggedCom RuggedOS < 3.12.1 Web UI Multiple Security Vulnerabilities | Nessus | SCADA | 2013/2/6 | 2024/7/24 | critical |
59502 | WellinTech KingSCADA 3.1 < 2012-04-16 user.db Base-64 Encoding Local Credentials Disclosure | Nessus | SCADA | 2012/6/14 | 2024/7/24 | high |
201036 | Rockwell Automation ThinManager ThinServer RCE (CVE-2024-5988) | Nessus | SCADA | 2024/6/26 | 2024/7/17 | critical |
155316 | Schneider Electric ISGG dc.exe File Upload RCE (CVE-2021-22803) | Nessus | SCADA | 2021/11/12 | 2024/7/17 | critical |
189991 | Rockwell FactoryTalk Services Platform < 6.40 Authentication Bypass | Nessus | SCADA | 2024/2/5 | 2024/5/31 | critical |
119845 | Advantech WebAccess webvrpcs.exe IOCTL 70022のスタックオーバーフロー | Nessus | SCADA | 2018/12/21 | 2024/7/24 | high |
118711 | デバイス属性のDNP3検出 | Nessus | SCADA | 2018/11/2 | 2024/7/17 | info |
109145 | Schneider Electric InTouch Machine Editionの検出 | Nessus | SCADA | 2018/4/18 | 2024/7/24 | info |
109146 | Schneider Electric InduSoft Web Studio の検出 | Nessus | SCADA | 2018/4/18 | 2024/7/24 | info |
106228 | Schneider Electric InduSoft Web Studio/InTouch Machine Edition<8.1のRCE | Nessus | SCADA | 2018/1/22 | 2024/7/17 | critical |
103533 | Trihedral VTScada 8.x<11.2.02の複数の脆弱性 | Nessus | SCADA | 2017/9/28 | 2024/5/20 | critical |
103534 | Trihedral VTScadaの検出 | Nessus | SCADA | 2017/9/28 | 2024/7/17 | info |
131704 | 3S CODESYS CmpWebServerHandlerV3のヒープベースのバッファオーバーフロー | Nessus | SCADA | 2019/12/4 | 2024/7/24 | critical |
152098 | CODESYS V2 Webサーバーの不適切な実装セキュリティチェック(2021-07) | Nessus | SCADA | 2021/7/27 | 2024/7/24 | critical |
149307 | CodeMeter Runtimeの予測可能な暗号化キー | Nessus | SCADA | 2021/5/6 | 2024/7/24 | critical |
149971 | Schneider Electric C-Gate < 2.11.6の複数の脆弱性 | Nessus | SCADA | 2021/5/26 | 2024/7/24 | high |
136182 | 3S CODESYS Runtime 3.x < 3.5.15.40 の複数の脆弱性 | Nessus | SCADA | 2020/4/30 | 2024/7/24 | critical |
50687 | RealWin < 2.1.10 複数のパケット型処理のオーバーフロー | Nessus | SCADA | 2010/11/23 | 2024/5/20 | critical |
23810 | DNP3 アウトステーション非送信請求メッセージサポート | Nessus | SCADA | 2006/12/11 | 2024/7/17 | medium |