Facebook Google Plus Twitter LinkedIn YouTube RSS Menu Search Resource - BlogResource - WebinarResource - ReportResource - Eventicons_066 icons_067icons_068icons_069icons_070

Siemens User Management Component V2.15.1.1 Multiple Vulnerabilities

Critical

Synopsis

CVE-2025-40795 um.Ris.exe Message 17 Stack-based Buffer Overflow (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H)

An unauthenticated, remote attacker can send a crafted message to cause a stack-based buffer overflow.

 

CVE-2025-40796 um.Ris.exe Out-of-bounds Read DoS (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H)

An unauthenticated, remote attacker can send a partial message causing an invalid memory access and crash in um.Ris.exe. 

 

CVE-2025-40797 um.Ris.exe Message 3 Out-of-bounds Read DoS (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H)

An unauthenticated, remote attacker can send an integer with a large value to crash um.Ris.exe.

 

CVE-2025-40798 um.Ris.exe Message 4 Out-of-bounds Read DoS (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H)

An unauthenticated, remote attacker can send an integer with a large value to crash um.Ris.exe.

Solution

Update UMC to V2.15.1.3 or later compatible version.

 

Siemens also provides the following workarounds: In non-networked scenarios/deployments block TCP ports 4002 and 4004 on machines with UMC installed. If the deployment is not using the 'RT Server' type of UMC machine, port 4004 can be blocked everywhere without impacting network functionality for all other UMC machine-types (Server, Ring-Server, Agent).

Disclosure Timeline

June 11, 2025: Tenable sends disclosure email.
June 12, 2025: Siemens acknowledges, provides case number.
July 7, 2025: Tenable asks for status update.
July 10, 2025: Siemens replies that the responsible party is out of the office and will get back next week.
July 15, 2025: Siemens responds that they are working on a fix but don't have a timeline yet.
August 5, 2025: Tenable asks for a status update.
August 6, 2025: Siemens replies that they are working on the fix and plan to release it with their September Advisory Day on September 9, 2025.
September 4, 2025: Tenable asks if Siemens is still on track to issue a fix and advisory on September 9 and reminds them that it is also our disclosure date.
September 4, 2025: Siemens acknowledges that they plan to publish on September 9.
September 8, 2025: Tenable shares draft with Siemens and asks for CVE identifiers.
September 8, 2025: Siemens replies with CVEs and shares their advisory draft.

All information within TRA advisories is provided “as is”, without warranty of any kind, including the implied warranties of merchantability and fitness for a particular purpose, and with no guarantee of completeness, accuracy, or timeliness. Individuals and organizations are responsible for assessing the impact of any actual or potential security vulnerability.

Tenable takes product security very seriously. If you believe you have found a vulnerability in one of our products, we ask that you please work with us to quickly resolve it in order to protect customers. Tenable believes in responding quickly to such reports, maintaining communication with researchers, and providing a solution in short order.

For more details on submitting vulnerability information, please see our Vulnerability Reporting Guidelines page.

If you have questions or corrections about this advisory, please email [email protected]

Risk Information

Tenable Advisory ID: TRA-2025-35
Affected Products:
User Management Component (UMC)
Risk Factor:
Critical

Advisory Timeline

September 9, 2025 - Initial release.